Media 000012077: Mandible
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000012077: Mandible
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000012077
Media type
Mesh
Object element or part
Mandible
Object represented
Object taxonomy
Basiliscus plumifrons
Object organization
Side
Left
Orientation
--
Short description
Basiliscus plumifrons left mandible
Full description
Migrated MorphoSource 1 Media File Title: Basiliscus plumifrons left mandible Migrated MorphoSource 1 Media Group Title: Partial Basiliscus plumifrons left mandible Migrated MorphoSource 1 Media Group Description: MicroCT scan of left jaw
Creator
--
Date created
--
Date uploaded
April 30, 2016
FILE OBJECT DETAILS Field Definitions
File name
Basiliscus-plumifrons_oriented.stl
File format(s)
STL
File size
273 MB
Points
682992
Polygons
1366280
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
871.373, 181.729, 364.970
Centroid coordinates
375.311, 6.231, 107.642
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric EVS-RS9 micro CT, University of Utah Small Animal Imaging Facility (University of Utah)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF Graduate Research Fellowship
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Museum of Comparative Zoology at Harvard University provided access to these dataoriginally appearing in Melstrom, 2017 , the collection of which was funded by a NSF Graduate Research Fellowship. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
mcz:R-19487
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric EVS-RS9 micro CT
Device facility
University of Utah Small Animal Imaging Facility (University of Utah)
Creator
Samer Merchant
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000012077: Mandible [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Samer Merchant
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000012077: Mandible [Mesh] [Etc] (this media)