Media 000018283: Skull
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000018283
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Stegoceras validum
Side
--
Orientation
--
Short description
MicroCT scan data of Stegoceras validum (UALVP 2) in DICOM format
Full description
Migrated MorphoSource 1 Media File Title: MicroCT scan data of Stegoceras validum (UALVP 2) in DICOM format Migrated MorphoSource 1 Media Group Title: MicroCT scan data in DICOM format
Creator
--
Date created
--
Date uploaded
October 25, 2016

FILE OBJECT DETAILS Field Definitions

File name
WitmerLab_Stegoceras_UALVP2_DICOM.zip
File format(s)
ZIP archive, DICOM
File size
566 MB
Image width
754
Image height
1024
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.210000
Y pixel spacing
0.210000
Z pixel spacing
0.250000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
514

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
National Science Foundation IOB-0517257, IOS-1050154, IOS-1456503
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: WitmerLab at Ohio University provided access to these dataoriginally appearing in The Visible Interactive Pachycephalosaur , the collection of which was funded by NSF grants to LM Witmer.. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ualvp:UALVP-2 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
--
Voltage
450
Power
--
Amperage
1300
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000018283: Skull [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000018283: Skull [CTImageSeries] [Etc] (this media)