Media 000018285: Partial Skull
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000018285: Partial Skull
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000018285
Media type
Mesh
Object element or part
partial skull
Object represented
Object taxonomy
Sphaerotholus edmontonensis
Object organization
Side
--
Orientation
--
Short description
Sphaerotholus edmontonensis (MRF 360) STL
Full description
Migrated MorphoSource 1 Media File Title: Sphaerotholus edmontonensis (MRF 360) STL Migrated MorphoSource 1 Media Group Title: Sphaerotholus edmontonensis (MRF 360) STL
Creator
--
Date created
--
Date uploaded
October 25, 2016
FILE OBJECT DETAILS Field Definitions
File name
WitmerLab_Sphaerotholus_MRF360.stl
File format(s)
STL
File size
57.2 MB
Points
599521
Polygons
1199898
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
102.636, 81.072, 124.091
Centroid coordinates
53.475, 55.508, 62.013
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
National Science Foundation IOB-0517257, IOS-1050154, IOS-1456503
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: WitmerLab at Ohio University provided access to these dataoriginally appearing in The Visible Interactive Pachycephalosaur , the collection of which was funded by NSF grants to LM Witmer.. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
mrf:MRF 360
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000018285: Partial Skull [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000018285: Partial Skull [Mesh] [Etc] (this media)