Media 000025796: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000025796
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Homoroselaps lacteus
Object organization
Side
--
Orientation
--
Short description
Tiff stack
Full description
Migrated MorphoSource 1 Media File Title: Tiff stack Migrated MorphoSource 1 Media Group Title: CT scan of CAS-H-173258, Homoloselaps lacteus
Creator
--
Date created
--
Date uploaded
April 14, 2017

FILE OBJECT DETAILS Field Definitions

File name
Homoloselaps-lacteus-CAS173258.zip
File format(s)
ZIP archive, TIFF
File size
357 MB
Image width
797
Image height
594
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.015948
Y pixel spacing
0.015948
Z pixel spacing
0.015948
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
437

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, GE Sensing & Inspection Technologies / phoenix|x-ray (Baker Hughes)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
California Academy of Sciences
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
University of Florida
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object CAS:HERP:173258 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
GE Sensing & Inspection Technologies / phoenix|x-ray (Baker Hughes)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.333
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1000
Voltage
90
Power
0.018
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000025796: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000025796: Element Unspecified [CTImageSeries] [Etc] (this media)