Media 000027952: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000027952
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Pseudanos gracilis
Side
--
Orientation
--
Short description
Pseudanos gracilis - Slice Data
Full description
Migrated MorphoSource 1 Media File Title: Pseudanos gracilis - Slice Data Migrated MorphoSource 1 Media Group Title: Pseudanos gracilis
Creator
--
Date created
--
Date uploaded
June 29, 2017

FILE OBJECT DETAILS Field Definitions

File name
Pseudanos-gracilis-2.zip
File format(s)
ZIP archive, JPEG
File size
69.6 MB
Image width
320
Image height
384
Color space
--
Color depth
8/8/8
Compression
--
X pixel spacing
0.049700
Y pixel spacing
0.049700
Z pixel spacing
0.049700
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,591

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Academy of Natural Sciences of Drexel University
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701665
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Academy of Natural Sciences of Drexel University provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ANSP:FISH:137595 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Thaddeus Buser
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
60
Power
--
Amperage
133
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000027952: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Thaddeus Buser
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000027952: Element Unspecified [CTImageSeries] [Etc] (this media)