Media 000042253: Hindlimb
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000042253
Media type
Volumetric Image Series
Object element or part
Hindlimb
Object represented
Object taxonomy
Perodicticus potto
Object organization
Side
--
Orientation
--
Short description
microCT Volume File
Full description
Migrated MorphoSource 1 Media File Title: microCT Volume File Migrated MorphoSource 1 Media Group Title: microCT Volume File Migrated MorphoSource 1 Media Group Description: Specimen is stained in iodine. Reversed chirality.
Creator
--
Date created
--
Date uploaded
February 26, 2018

FILE OBJECT DETAILS Field Definitions

File name
Perodicticus_hind.zip
File format(s)
ZIP archive, TIFF
File size
1.93 GB
Image width
1782
Image height
1067
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
0.068452
Y pixel spacing
0.068452
Z pixel spacing
0.068452
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,430

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Duke Lemur Center
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1552848, NSF BCS 1317525
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: The Duke Lemur Center provided access to these data, originally appearing in Yapuncich et al. (2019), the collection of which was funded by NSF BCS 1552848 to Doug M. Boyer and NSF BCS 1317525 to Doug M. Boyer and Erik R. Seiffert. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dlc:917f was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Addison Kemp, Mackenzie Aguilar
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
193
Power
0.023546
Amperage
122
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000042253: Hindlimb [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Addison Kemp, Mackenzie Aguilar
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000042253: Hindlimb [CTImageSeries] [Etc] (this media)