Media 000043626: Skeleton
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000043626
Media type
Volumetric Image Series
Object element or part
Skeleton
Object represented
Object taxonomy
Isthmohyla pseudopuma
Object organization
Side
--
Orientation
--
Short description
CT scan of mcz-herp-a-29108, Isthmohyla pseudopuma pseudopuma
Full description
Migrated MorphoSource 1 Media File Title: CT scan of mcz-herp-a-29108, Isthmohyla pseudopuma pseudopuma Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
March 14, 2018

FILE OBJECT DETAILS Field Definitions

File name
MCZ-A29108_H_pseudopuma_pseudopuma_Rec.zip
File format(s)
ZIP archive, TIFF
File size
1.29 GB
Image width
712
Image height
948
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.034090
Y pixel spacing
0.034090
Z pixel spacing
0.034090
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,356

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Museum of Comparative Zoology Scanning Facility (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714; overt TCN; NSF DBI-1702263
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:Herp:A-29108 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
Matt Gage
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
5
Projections
1200
Voltage
40
Power
0.0074
Amperage
185
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000043626: Skeleton [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matt Gage
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000043626: Skeleton [CTImageSeries] [Etc] (this media)