Media 000048542: 16bit Tiff
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000048542
Media type
Volumetric Image Series
Object element or part
16bit tiff
Object represented
Object taxonomy
Eleutherodactylus eneidae
Side
--
Orientation
--
Short description
Zstack
Full description
Migrated MorphoSource 1 Media File Title: Zstack
Creator
--
Date created
--
Date uploaded
May 15, 2018

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
113 MB
Image width
378
Image height
982
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.029579
Y pixel spacing
0.029579
Z pixel spacing
0.029579
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,306

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Florida Museum of Natural History, University of Florid
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:100532 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1900
Voltage
70
Power
0.014
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000048542: 16bit Tiff [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000048542: 16bit Tiff [CTImageSeries] [Etc] (this media)