Media 000051655: Element Unspecified
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000051655
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Sectoria atriceps
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Whole ethanol fixed specimen
Creator
--
Date created
--
Date uploaded
June 26, 2018

FILE OBJECT DETAILS Field Definitions

File name
UF_191214_zstack.zip
File format(s)
ZIP archive, TIFF
File size
107 MB
Image width
383
Image height
480
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.039145
Y pixel spacing
0.039145
Z pixel spacing
0.039145
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,873

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Overt TCN, NSF DBI1701753
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Fish:191214 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zach Randall
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
840
Voltage
60
Power
0.012
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000051655: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Zach Randall
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000051655: Element Unspecified [CTImageSeries] [Etc] (this media)