Media 000055495: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000055495
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Gastrotheca dysprosita
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Whole body ethanol preserved
Creator
--
Date created
--
Date uploaded
July 26, 2018

FILE OBJECT DETAILS Field Definitions

File name
UF-Herp-30080.zip
File format(s)
ZIP archive, TIFF
File size
2.14 GB
Image width
753
Image height
1096
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.041388
Y pixel spacing
0.041388
Z pixel spacing
0.041388
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,022

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
University of Florida
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
oVertTCN, NSF DBI1701714
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:30080 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Daniel Paluh
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1500
Voltage
80
Power
0.016
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000055495: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Daniel Paluh
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000055495: Element Unspecified [CTImageSeries] [Etc] (this media)