Media 000056196: Skull Part 1
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000056196
Media type
Volumetric Image Series
Object element or part
Skull - part 1
Object represented
Object taxonomy
Ichthyosaurus prostaxalis
Object organization
Side
--
Orientation
--
Short description
Raw CT data of BMT 1955.G35.1 Part 1
Full description
Migrated MorphoSource 1 Media File Title: Raw CT data of BMT 1955.G35.1 Part 1 Migrated MorphoSource 1 Media Group Title: Raw CT scans of BMT 1955.G35.1
Creator
--
Date created
--
Date uploaded
August 08, 2018

FILE OBJECT DETAILS Field Definitions

File name
anterior_snout540.zip
File format(s)
ZIP archive, DICOM
File size
108 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.560000
Y pixel spacing
0.560000
Z pixel spacing
1.250000
Pixel spacing units
Mm
Slice thickness
1.250000
Number of images in set
540

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Lightspeed Pro 16 CT scanner, Queen Mother Hospital for Animals (Royal Veterinary College)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object bmt:1955.G35.1 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Lightspeed Pro 16 CT scanner
Device facility
Queen Mother Hospital for Animals (Royal Veterinary College)
Creator
Renate Weller
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
120
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000056196: Skull Part 1 [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Renate Weller
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000056196: Skull Part 1 [CTImageSeries] [Etc] (this media)