Media 000056540: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000056540
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Symphodus mediterraneus
Side
--
Orientation
--
Short description
Symphodus mediterraneus
Full description
Migrated MorphoSource 1 Media File Title: Symphodus mediterraneus Migrated MorphoSource 1 Media Group Title: Symphodus mediterraneus
Creator
--
Date created
--
Date uploaded
August 15, 2018

FILE OBJECT DETAILS Field Definitions

File name
Symphodus-mediterraneus--3-.zip
File format(s)
ZIP archive, JPEG
File size
405 MB
Image width
2022
Image height
1813
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
0.025900
Y pixel spacing
0.025900
Z pixel spacing
0.025900
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,781

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
oVert TCN, NSF DBI1701665, NSF DBI1702421
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Kory Evans-Jackson provided access to these dataoriginally appearing in , the collection of which was funded by. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Fishes:46104 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
65
Power
--
Amperage
123
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000056540: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000056540: Element Unspecified [CTImageSeries] [Etc] (this media)