Media 000063804: Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000063804
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Proscelotes eggeli
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
November 08, 2018

FILE OBJECT DETAILS Field Definitions

File name
CAS-herps-168960_Proscelotes-eggeli.zip
File format(s)
ZIP archive, TIFF
File size
63.4 MB
Image width
290
Image height
210
Color space
BlackIsZero
Color depth
8
Compression
--
X pixel spacing
0.072060
Y pixel spacing
0.072060
Z pixel spacing
0.072060
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,000

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, University of Michigan Museum of Zoology, Research Museums Center (University of Michigan)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
California Academy of Sciences
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714; NSF DBI-1701773; oVert TCN
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object CAS:HERP:168960 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
University of Michigan Museum of Zoology, Research Museums Center (University of Michigan)
Creator
Gregory Pandelis, Coen Long
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
250
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1601
Voltage
85
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000063804: Whole Body [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Gregory Pandelis, Coen Long
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000063804: Whole Body [CTImageSeries] [Etc] (this media)