Media 000071185: Body
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000071185
Media type
Mesh
Object element or part
Body
Object represented
Object taxonomy
Rhinophrynus dorsalis
Side
--
Orientation
--
Short description
3D Mesh
Full description
Migrated MorphoSource 1 Media File Title: 3D Mesh Migrated MorphoSource 1 Media Group Title: CT data and derivatives
Creator
--
Date created
--
Date uploaded
March 04, 2019

FILE OBJECT DETAILS Field Definitions

File name
Rhinophrynus_dorsalis_UF-H-13375-4.stl
File format(s)
STL
File size
460 MB
Points
4792132
Polygons
9648756
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
51.086, 35.054, 71.815
Centroid coordinates
0.243, -0.480, -3.786
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Florida Museum of Natural History
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Big Data From Small Fossils: Curation and Digitization of Major Microvertebrate Paleontology Collections at The Florida Museum of Natural History NSF #DBI-1756306
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:13375 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Maria Camila Vallejo-Pareja
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1800
Voltage
100
Power
0.02
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000071249: Whole Body [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Maria Camila Vallejo-Pareja
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000071249: Whole Body [CTImageSeries] [Etc] was processed to create derived Media 000071185: Body [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Maria Camila Vallejo-Pareja
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000071185: Body [Mesh] [Etc] (this media)