Media 000004357: Cranium + Mandible
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000004357
Media type
Volumetric Image Series
Object element or part
cranium + mandible
Object represented
Object taxonomy
Tarsius syricta syricta
Side
NotApplicable
Orientation
--
Short description
.tiff image stack of microCT scan, Tarsius, DPC-0127
Full description
Migrated MorphoSource 1 Media File Title: .tiff image stack of microCT scan, Tarsius, DPC-0127 Migrated MorphoSource 1 Media Group Title: .tiff image stack of microCT scan, Tarsius, DPC OST 127 Migrated MorphoSource 1 Media File Description: adult Migrated MorphoSource 1 Media Group Description: Part of skeleton
Creator
--
Date created
--
Date uploaded
January 06, 2015

FILE OBJECT DETAILS Field Definitions

File name
Allen_DPC0127_Tarsius.zip
File format(s)
ZIP archive
File size
716 MB
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
X pixel spacing
0.022222
Y pixel spacing
0.022222
Z pixel spacing
0.022222
Pixel spacing units
Mm
Slice thickness
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
PIs: K.L. Allen and R.F. KayGrant support from Leakey Foundation (#181951) and NSF DDIG (#BCS-1232534)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: K.L. Allen provided access to these dataoriginally appearing in Allen 2014 PhD dissertation NSF and the Leakey Foundation. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dpc:ost:127 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
K.L. Allen
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
1000
Voltage
100
Power
--
Amperage
171
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000004357: Cranium + Mandible [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
K.L. Allen
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000004357: Cranium + Mandible [CTImageSeries] [Etc] (this media)