Media 000004659: First Metatarsal
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000004659
Media type
Mesh
Object element or part
First metatarsal
Object represented
Object taxonomy
Aegyptopithecus zeuxis
Side
Left
Orientation
--
Short description
Smooth Surface Mesh
Full description
Migrated MorphoSource 1 Media File Title: Smooth Surface Mesh Migrated MorphoSource 1 Media Group Title: Smooth Surface Mesh
Creator
--
Date created
--
Date uploaded
February 04, 2015

FILE OBJECT DETAILS Field Definitions

File name
Aegyptopithecus-zeuxis-DPC-13318.ply
File format(s)
PLY
File size
12.3 MB
Points
174582
Polygons
337792
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
30.116, 9.720, 6.869
Centroid coordinates
-0.039, 0.165, -0.301
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical vivaCT 75, Stony Brook University Center for Biotechnology (Stony Brook University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Grant numbers: BCS 1317525 (to D.M.B.); BCS 1317029 (to C.M.O.); Grant sponsor: National Science Foundation; Grant sponsor: The Wenner-Gren foundation (to C.M.O.); Grant sponsor: Turkana Basin Institute Graduate Fellowship (to K.E.G.); Grant sponsor: The Leakey Foundation (to B.A.P.); BCS 1317047 (to B.A.P.)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in Goodenberger et al. 2015 Turkana Basin Institute Graduate Fellowship (to K.E.G.). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dpc:13318 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical vivaCT 75
Device facility
Stony Brook University Center for Biotechnology (Stony Brook University)
Creator
Biren A. Patel, Ksenia Sokolova
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000004659: First Metatarsal [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Biren A. Patel, Ksenia Sokolova
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000004659: First Metatarsal [Mesh] [Etc] (this media)