Media 000098705: Head
Open Download
Type Image
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000098705
Media type
Image
Object element or part
Head
Object represented
Object taxonomy
Fukomys mechowi
Object organization
Side
--
Orientation
--
Short description
Fukomys mechowi
Full description
Migrated MorphoSource 1 Media File Title: Fukomys mechowi Migrated MorphoSource 1 Media Group Title: DiceCT stack
Creator
--
Date created
--
Date uploaded
January 16, 2020

FILE OBJECT DETAILS Field Definitions

File name
Fukomys-IKI-stack.tif
File format(s)
TIFF
File size
1.85 GB
Image width
1250
Image height
958
Color space
BlackIsZero
Color depth
8
Compression
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Cambridge Biotomography Centre (University of Cambridge)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Phil Cox and colleagues provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object cahs:FM-IKI-3 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Cambridge Biotomography Centre (University of Cambridge)
Creator
Keturah Smithson
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
164
Power
--
Amperage
162
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000098705: Head [Image] [Etc] (this media).

Processing Details Field Definitions

Creator
Keturah Smithson
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000098705: Head [Image] [Etc] (this media)