Media 000115564: Skeleton Stl
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000115564
Media type
Mesh
Object element or part
skeleton stl
Object represented
Object taxonomy
Colostethus latinasus
Object organization
Side
--
Orientation
--
Short description
skeleton stl
Full description
Migrated MorphoSource 1 Media File Title: skeleton stl Migrated MorphoSource 1 Media Group Title: skeleton and skull STLs
Creator
--
Date created
--
Date uploaded
May 04, 2020

FILE OBJECT DETAILS Field Definitions

File name
MCZ91234_skeleton.stl
File format(s)
STL
File size
67.8 MB
Points
710566
Polygons
1422221
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
23.570, 6.745, 30.165
Centroid coordinates
1.140, 0.317, 0.513
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Museum of Comparative Zoology Scanning Facility (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:Herp:A-91234 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
Matt Gage
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1.175
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
5
Projections
960
Voltage
45
Power
0.007965
Amperage
177
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000079821: Skeleton [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Matt Gage
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000079821: Skeleton [CTImageSeries] [Etc] was processed to create derived Media 000115564: Skeleton Stl [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000115564: Skeleton Stl [Mesh] [CT] (this media)