Media 000008140: Cranial Elements
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000008140
Media type
Mesh
Object element or part
Cranial elements
Object represented
Object taxonomy
Mubhammys vadumensis
Side
--
Orientation
--
Short description
Mubhammys vadumensis
Full description
Migrated MorphoSource 1 Media File Title: Mubhammys vadumensis Migrated MorphoSource 1 Media Group Title: Surface reconstruction Migrated MorphoSource 1 Media Group Description: Scan no. Sallam_DPC_9_7_2015C
Creator
--
Date created
--
Date uploaded
November 23, 2015

FILE OBJECT DETAILS Field Definitions

File name
DPC-14324.ply
File format(s)
PLY
File size
269 MB
Points
3488618
Polygons
6978400
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
16.676, 11.330, 11.113
Centroid coordinates
15.089, 8.164, 9.259
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Hesham Sallam and Erik Seiffert provided access to these dataoriginally appearing in PeerJ 4:e1717 , the collection of which was funded by the U.S. National Science Foundation. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dpc:14324 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Hesham Sallam
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1800
Voltage
120
Power
0.01332
Amperage
111
Surrounding material
none
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000010516: Skull [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Hesham Sallam
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000010516: Skull [CTImageSeries] [Etc] was processed to create derived Media 000008140: Cranial Elements [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Hesham Sallam
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000008140: Cranial Elements [Mesh] [Etc] (this media)