Media 000012727: Cranium
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000012727
Media type
Volumetric Image Series
Object element or part
Cranium
Object represented
Object taxonomy
Propithecus sp.
Side
Midline
Orientation
--
Short description
Zipped Tiff Stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped Tiff Stack Migrated MorphoSource 1 Media Group Title: Zipped Tiff Stack
Creator
--
Date created
--
Date uploaded
May 20, 2016

FILE OBJECT DETAILS Field Definitions

File name
Boyer_DPC13625_prop_zstack.zip
File format(s)
ZIP archive, TIFF
File size
4.38 GB
Image width
1617
Image height
1416
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.033076
Y pixel spacing
0.033076
Z pixel spacing
0.033076
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,941

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1440742 (to D. M. Boyer and G. F. Gunnell), and NSF BCS 1552848 (to D. M. Boyer)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer and the Duke Division of Fossil Primates provided access to these dataoriginally appearing in Boyer et al. (2016) , the collection of which was funded by NSF BCS 1440742 and 1552848. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dpc:13625 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer, Miles Schaeffer
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
1500
Voltage
90
Power
0.024300000000000002
Amperage
270
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000012727: Cranium [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Doug Boyer, Miles Schaeffer
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000012727: Cranium [CTImageSeries] [Etc] (this media)