Media 000000389: Second Mandibular Molar [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

Interactive/Embeddable Media Preview is currently unavailable. Please check back later.

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000000389
Media type
CTImageSeries
File format(s)
application/dicom
File size
872,918 bytes
Object element or part
second mandibular molar
Side
Unknown
Orientation
--
Short description
Zipped microCT image stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped microCT image stack Migrated MorphoSource 1 Media Group Title: Raw Surface file Migrated MorphoSource 1 Media File Description: zipped image stack. dicom format. Migrated MorphoSource 1 Media Group Description: Raw surface.
Creator
--
Date created
--
Date uploaded
June 28, 2013
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
X pixel spacing
0.018
Y pixel spacing
0.018
Z pixel spacing
0.018
Pixel spacing units
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40, Stony Brook University Center for Biotechnology (Stony Brook University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
AMNH Dept of Mammalogy
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
American Society of Mammalogists Grant Evolving Earth Foundation NSF DDIG BCS-0622544
Publisher
--
Cite as
originally appearing in
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:mammals:m-17356 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40
Device facility
Stony Brook University Center for Biotechnology (Stony Brook University)
Creator
Doug Boyer
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
1
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000000389: Second Mandibular Molar [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000000389: Second Mandibular Molar [CTImageSeries] [Etc] (this media)