Media 000000568: Skull
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000000568
Media type
Mesh
Object element or part
Skull
Object represented
--
Side
Unknown
Orientation
--
Short description
Smaug Giganteus Surface File
Full description
Migrated MorphoSource 1 Media File Title: Smaug Giganteus Surface File Migrated MorphoSource 1 Media Group Title: Smaug Giganteus Surface File Migrated MorphoSource 1 Media File Description: Down sampled STL from original CT Data Migrated MorphoSource 1 Media Group Description: Down sampled STL from original CT Data
Creator
--
Date created
--
Date uploaded
August 15, 2013

FILE OBJECT DETAILS Field Definitions

File name
80965_ms_media_media_680_original.stl
File format(s)
STL
File size
128 MB
Points
467897
Polygons
689872
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
58.185, 41.406, 26.006
Centroid coordinates
9.978, 3.243, -3.746
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
Dr. Edward Stanley
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
Jimmy Thostenson
Event date
--
Software
--
Description
Dark Field & Bright Field
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000000568: Skull [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Jimmy Thostenson
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000000568: Skull [Mesh] [Etc] (this media)