Media 000001002: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000001002
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Eulemur fulvus fulvus
Side
Unknown
Orientation
--
Short description
microCT scan of DPC057 skull
Full description
Migrated MorphoSource 1 Media File Title: microCT scan of DPC057 skull Migrated MorphoSource 1 Media Group Title: microCT scan of DPC OST 57 skull Migrated MorphoSource 1 Media File Description: Compressed folder with .tiff files (Z stack) Migrated MorphoSource 1 Media Group Description: Part of skeleton Compressed folder with .tiff files (Z stack)
Creator
--
Date created
--
Date uploaded
September 23, 2013

FILE OBJECT DETAILS Field Definitions

File name
Allen_Eulemur_DUPC057_skull_Zstack.zip
File format(s)
ZIP archive, TIFF
File size
1.07 GB
Image width
1164
Image height
1252
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.050111
Y pixel spacing
0.050111
Z pixel spacing
0.050111
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,923

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
PIs: R.F. Kay, K.L. AllenGrant support from the Leakey Foundation (#181951) and NSF DDIG (#BCS-1232534)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: K.L. Allen provided access to these dataoriginally appearing in Allen 2014 PhD dissertation NSF and the Leakey Foundation. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dpc:ost:57 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
K.L. Allen
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
2100
Voltage
180
Power
--
Amperage
170
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000001002: Skull [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
K.L. Allen
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource