Media 000001551: Misc Postcranials 5 [Image] [Etc]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000001551
Media type
Image
Object element or part
misc postcranials 5
Side
Unknown
Orientation
--
Short description
Raw Surface file
Full description
Migrated MorphoSource 1 Media File Title: Raw Surface file Migrated MorphoSource 1 Media Group Title: Raw Surface file Migrated MorphoSource 1 Media File Description: Raw surface. Migrated MorphoSource 1 Media Group Description: Raw surface.
Creator
--
Date created
--
Date uploaded
October 24, 2013

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
55.3 KB
Image width
1362
Image height
1013
Color space
RGB
Color depth
8/8/8
Compression
LZW

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
IP holder
University of California Regents; University of California Museum of Paleontology
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
originally appearing in
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ucmp:v:38762 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
3142
Voltage
155
Power
--
Amperage
150
Surrounding material
none
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000001553: Misc Postcranials 5 [CTImageSeries] [Etc] .

Processing Details

Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000001553: Misc Postcranials 5 [CTImageSeries] [Etc] was processed to create derived Media 000001551: Misc Postcranials 5 [Image] [Etc] (this media).

Processing Details

Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000001551: Misc Postcranials 5 [Image] [Etc] (this media)