Media 000001567: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000001567: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000001567
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Galago senegalensis
Object organization
Side
Unknown
Orientation
--
Short description
.tiff image stack. microCT scan of DPC009 Galago skull
Full description
Migrated MorphoSource 1 Media File Title: .tiff image stack. microCT scan of DPC009 Galago skull Migrated MorphoSource 1 Media Group Title: .tiff image stack. microCT scan of DPC OST 9 Galago skull
Creator
--
Date created
--
Date uploaded
October 24, 2013
FILE OBJECT DETAILS Field Definitions
File name
20682_ms_media_media_1743_archive_.zip
File format(s)
ZIP archive, TIFF
File size
1.26 GB
Image width
1389
Image height
1459
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.027882
Y pixel spacing
0.027882
Z pixel spacing
0.027882
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,952
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Leakey Foundation grant #181951 (PIs: K.L. Allen, R.F. Kay)
Publisher
--
Cite as
originally appearing in
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
dpc:ost:9
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
K.L. Allen
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
2600
Voltage
160
Power
--
Amperage
175
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000001567: Skull [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
K.L. Allen
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000001567: Skull [CTImageSeries] [Etc] (this media)