Media 000002370: Femur
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000002370
Media type
Volumetric Image Series
Object element or part
Femur
Object represented
Object taxonomy
Marcgodinotius indicus
Object organization
Side
Right
Orientation
--
Short description
GU 794 Right Femur
Full description
Migrated MorphoSource 1 Media File Title: GU 794 Right Femur Migrated MorphoSource 1 Media Group Title: Smooth Surface Mesh
Creator
--
Date created
--
Date uploaded
May 20, 2014

FILE OBJECT DETAILS Field Definitions

File name
GU_794_R_Femur.zip
File format(s)
ZIP archive
File size
229 MB
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
X pixel spacing
0.018390
Y pixel spacing
0.018390
Z pixel spacing
0.018390
Pixel spacing units
Mm
Slice thickness
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Garhwal University
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object gu:794 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Jimmy Thostenson
Event date
--
Software
--
Description
Dark Field & Bright Field
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1800
Voltage
185
Power
0.0135
Amperage
73
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000002370: Femur [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Jimmy Thostenson
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000002370: Femur [CTImageSeries] [Etc] (this media)