Media 000004361: Maxilla
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000004361: Maxilla
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000004361
Media type
Mesh
Object element or part
maxilla
Object represented
Object taxonomy
Beelzebufo ampinga
Object organization
Side
Left
Orientation
--
Short description
FMNH_PR_2512_L_MAX.ply
Full description
Migrated MorphoSource 1 Media File Title: FMNH_PR_2512_L_MAX.ply Migrated MorphoSource 1 Media Group Title: FMNH_PR_2512_L_MAX Migrated MorphoSource 1 Media File Description: pars facialis Migrated MorphoSource 1 Media Group Description: pars facialis
Creator
--
Date created
--
Date uploaded
January 06, 2015
FILE OBJECT DETAILS Field Definitions
File name
FMNH_PR_2512_L_MAX.ply
File format(s)
PLY
File size
35.7 MB
Points
517617
Polygons
1033094
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
7.728, 11.022, 9.666
Centroid coordinates
5.484, 6.136, 5.394
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40, Stony Brook University Center for Biotechnology (Stony Brook University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Mahajanga Basin Project
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
This work was partially funded by grants from the National Science Foundation ((DEB-9224396, EAR-9418816, EAR-9706302, DEB-9904045, EAR-0106477, EAR-0116517, EAR-0446488, EAR-0116517) and the National Geographic Society (1999, 2001, 2004, 2009) to David W. Krause.
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Joseph R Groenke provided access to these dataoriginally appearing in PloS ONE doi:10.1371/journal.pone.0087236.g015 National Science Foundation and National Geographic. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
FMNH:PR:2512
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40
Device facility
Stony Brook University Center for Biotechnology (Stony Brook University)
Creator
Groenke
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
70
Power
--
Amperage
23
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000004360: Maxilla [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Groenke
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000004360: Maxilla [CTImageSeries] [Etc]
was processed
to create
derived
Media 000004361: Maxilla [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Groenke
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000004361: Maxilla [Mesh] [Etc] (this media)