Media 000005399: Calcaneus
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000005399: Calcaneus
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000005399
Media type
Volumetric Image Series
Object element or part
calcaneus
Object represented
Object taxonomy
Caenopithecus lemuroides
Object organization
Side
Right
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: this media group contains a raw ct scan and a smoothed mesh file extracted from it.
Creator
--
Date created
--
Date uploaded
April 27, 2015
FILE OBJECT DETAILS Field Definitions
File name
NMB_Eh-719_Caenopithecus_R_Calcaneus.zip
File format(s)
ZIP archive, TIFF
File size
229 MB
Image width
430
Image height
724
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.030275
Y pixel spacing
0.030275
Z pixel spacing
0.030275
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
466
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
Naturhistorisches Museum Basel
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1317525 (to DMB & ERS) NSF BCS 1304045 (to DMB & EMS)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in Seiffert et al. (2015) , the collection of which was funded by NSF BCS 1317525 & NSF BCS 1304045. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
nmb:eh:719
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
Jimmy Thostenson
Event date
--
Software
--
Description
0.2 mm Cu filter used
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1570
Voltage
140
Power
0.014
Amperage
100
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000005399: Calcaneus [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Jimmy Thostenson
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000005399: Calcaneus [CTImageSeries] [Etc] (this media)