Media 000006377: Rostrum And Mandible
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000006377
Media type
Volumetric Image Series
Object element or part
Rostrum and Mandible
Object represented
Object taxonomy
Otolemur crassicaudatus
Object organization
Side
Midline
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: CT Volume Data Migrated MorphoSource 1 Media Group Description: Part of complete skull, zoomed to region of interest
Creator
--
Date created
--
Date uploaded
August 11, 2015

FILE OBJECT DETAILS Field Definitions

File name
StClair_rescan_AMNH_116247_Otolemur_dental_zstack.zip
File format(s)
ZIP archive, TIFF
File size
1.76 GB
Image width
960
Image height
1266
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.021184
Y pixel spacing
0.021184
Z pixel spacing
0.021184
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,532

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
AMNH Dept of Mammalogy
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1304045 and a research grant from Trinity College of Arts and Sciences
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Chris Wall provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Mammals:M-116247 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Elizabeth St Clair, Callie Crawford
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1800
Voltage
115
Power
0.013224999999999999
Amperage
115
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000006377: Rostrum And Mandible [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Elizabeth St Clair, Callie Crawford
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000006377: Rostrum And Mandible [CTImageSeries] [Etc] (this media)