Media 000009763: Scan 60238 [Mesh] [Etc]
Represents:
Biological Specimen
Not in Collection

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000009763
Media type
Mesh
File format(s)
application/ply
File size
18,228,053 bytes
Object element or part
Scan 60238
Side
Midline
Orientation
--
Short description
Surface mesh generated from labels
Full description
Migrated MorphoSource 1 Media File Title: Surface mesh generated from labels Migrated MorphoSource 1 Media Group Title: Median Ocellus Migrated MorphoSource 1 Media File Description: Label key:\\r\\nGreen - Lens,\\r\\nCyan - Retina,\\r\\nRed - Iris,\\r\\nMagenta - Retinula cell axons,\\r\\nGrey - Cuticle,\\r\\nOrange - Vitreous body,\\r\\nBlue - Descending axons Migrated MorphoSource 1 Media Group Description: Transform relative to lateral ocellus:<br>translation: 0 0 0,<br>rotation: 0 0 1 0,<br>scaleFactor: 1 1 1,<br>scaleOrientation: 0 0 1,<br>center: 0 0 0<br>Downsampled to 1.5 micron resolution
Creator
--
Date created
--
Date uploaded
March 03, 2016
Points
337,557
Polygons
675,085
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
512.306, 667.511, 620.437
Centroid coordinates
304.055, 376.435, 279.258
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Diamond Manchester Imaging Branchline (I13-2), I13: X-ray Imaging and Coherence (Diamond Light Source Ltd)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Open Download
Download reviewer
--
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
IP holder(s) (Name, Type)
--
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Additial usage agreement
None
Media preview mode
--

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object lu:1_15_EI_M_4B was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Diamond Manchester Imaging Branchline (I13-2)
Device facility
I13: X-ray Imaging and Coherence (Diamond Light Source Ltd)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000009751: Scan 60238 [CTImageSeries] [Etc] .

Processing Details

Creator
--
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000009751: Scan 60238 [CTImageSeries] [Etc] was processed to create derived Media 000009763: Scan 60238 [Mesh] [Etc] (this media).

Processing Details

Creator
--
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000009763: Scan 60238 [Mesh] [Etc] (this media)