Media 000013109: Mandible
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000013109: Mandible
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS
Media ID
000013109
Media type
Mesh
Object element or part
Mandible
Object represented
Object taxonomy
Cheirogaleus medius
Object organization
Side
Midline
Orientation
--
Short description
Smooth Surface Mesh of Mandible
Full description
Migrated MorphoSource 1 Media File Title: Smooth Surface Mesh of Mandible Migrated MorphoSource 1 Media Group Title: Zipped Tiff Stack
Creator
--
Date created
--
Date uploaded
May 25, 2016
FILE OBJECT DETAILS
File format(s)
application/ply
File size
35.9 MB
Points
499930
Polygons
999834
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
22.521, 26.437, 28.577
Centroid coordinates
21.871, 17.238, 33.172
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
dpc:ost:34
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer, Miles Schaeffer
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
1800
Voltage
135
Power
0.01485
Amperage
110
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000012869: Cranium [CTImageSeries] [Etc].
Processing Details
Creator
Doug Boyer, Miles Schaeffer
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000012869: Cranium [CTImageSeries] [Etc]
was processed
to create
derived
Media 000013109: Mandible [Mesh] [Etc] (this media).
Processing Details
Creator
Doug Boyer, Miles Schaeffer
Date processed
--
Software
--
Description
--
Description attachment
None