Media 000013469: Ct Scan Of Skeleton And Skull [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

FILE OBJECT DETAILS

Media ID
000013469
Media type
Mesh
File format(s)
application/stl
File size
111 MB
Object element or part
CT scan of skeleton and skull
Side
NotApplicable
Orientation
--
Short description
STL of skull
Full description
Migrated MorphoSource 1 Media File Title: STL of skull Migrated MorphoSource 1 Media Group Title: CT scan of AMNH A 124113
Creator
--
Date created
--
Date uploaded
June 07, 2016
Points
1,145,603
Polygons
2,317,219
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
22.680, 25.113, 10.212
Centroid coordinates
-0.620, -0.128, -2.936
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
American Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
University of Florida
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:herpetology:a-124113 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1500
Voltage
110
Power
0.022
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000013636: Ct Scan Of Skeleton And Skull [CTImageSeries] [Etc] .

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000013636: Ct Scan Of Skeleton And Skull [CTImageSeries] [Etc] was processed to create derived Media 000013469: Ct Scan Of Skeleton And Skull [Mesh] [Etc] (this media).

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000013469: Ct Scan Of Skeleton And Skull [Mesh] [Etc] (this media)