Media 000015304: Capitate
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000015304
Media type
Volumetric Image Series
Object element or part
Capitate
Object represented
Object taxonomy
Daubentonia madagascariensis
Object organization
Side
Left
Orientation
--
Short description
Zipped Tiff Stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped Tiff Stack Migrated MorphoSource 1 Media Group Title: Zipped Tiff Stack, Raw Surface Mesh, Smooth Surface Mesh Migrated MorphoSource 1 Media Group Description: Correct chirality
Creator
--
Date created
--
Date uploaded
August 03, 2016

FILE OBJECT DETAILS Field Definitions

File name
USNM_199694_Daubentonia_capitate_L.zip
File format(s)
ZIP archive, TIFF
File size
75.3 MB
Image width
488
Image height
412
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.017003
Y pixel spacing
0.017003
Z pixel spacing
0.017003
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
285

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these data , the collection of which was funded by NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:MAMM:USNM 199694 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Gaal Almor, Mackenzie Aguilar
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1500
Voltage
131
Power
0.013099999999999999
Amperage
100
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000015304: Capitate [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Gaal Almor, Mackenzie Aguilar
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000015304: Capitate [CTImageSeries] [Etc] (this media)