Media 000015499: Lower M1
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000015499
Media type
Mesh
Object element or part
Lower M1
Object represented
Object taxonomy
Alouatta palliata
Side
Right
Orientation
--
Short description
Lower M1 Raw
Full description
Migrated MorphoSource 1 Media File Title: Lower M1 Raw Migrated MorphoSource 1 Media Group Title: Upper & Lower M1 Surfaces for Howler Wear Project Migrated MorphoSource 1 Media Group Description: Segmented from full skull scan represented by morphosource media group M4155-3788
Creator
--
Date created
--
Date uploaded
August 05, 2016

FILE OBJECT DETAILS Field Definitions

File name
4155_DU-LP-41_LM1.ply
File format(s)
PLY
File size
328 KB
Points
5119
Polygons
9999
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
8.463, 8.308, 5.008
Centroid coordinates
6.027, 8.757, 87.403
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
K.L. Allen
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Paul E. Morse provided access to these datawhich are derived from M4155-3788 provided by K.L. Allen and first appeared in Pampush et al. (2016). Raw data collection was funded by NSF DDIG and the Leakey Foundation to K.L. Allen. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object du:ea:LP41 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
James D. Pampush; Paul E. Morse
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
3142
Voltage
195
Power
--
Amperage
215
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000015499: Lower M1 [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
James D. Pampush, Paul E. Morse
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000015499: Lower M1 [Mesh] [Etc] (this media)