Media 000015534: Navicular
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000015534: Navicular
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS
Media ID
000015534
Media type
Mesh
Object element or part
navicular
Object represented
Object taxonomy
Notharctus tenebrosus
Object organization
Side
Left
Orientation
--
Short description
mesh file
Full description
Migrated MorphoSource 1 Media File Title: mesh file Migrated MorphoSource 1 Media Group Title: Volume data and derivative mesh files Migrated MorphoSource 1 Media File Description: correct chirality
Creator
--
Date created
--
Date uploaded
August 05, 2016
FILE OBJECT DETAILS
File format(s)
application/ply
File size
29.9 MB
Points
825138
Polygons
1650276
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
10.483, 6.018, 10.308
Centroid coordinates
17.936, 27.499, 13.816
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1558555 (to DM Boyer and GF Gunnell), 1440742 (to DM Boyer and GF Gunnell), 1440558 (to JI Bloch, 1552848 (to DM Boyer)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these data , the collection of which was funded by NSF BCS 1558555, 1440742, 1440558. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
dpc:25453
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Justin Gladman, Doug Boyer
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
1800
Voltage
220
Power
--
Amperage
91
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
private media that exists on MorphoSource but is inaccessible with current user permissions.
Processing Details
Creator
Justin Gladman, Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING
Derived
private media
was processed
to create
derived
Media 000015534: Navicular [Mesh] [CT] (this media).
Processing Details
Creator
Justin Gladman, Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None