Media 000015859: Whole Body Stl [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000015859
Media type
Mesh
File format(s)
application/stl
File size
57.2 MB
Object element or part
Whole body STL
Side
--
Orientation
--
Short description
STL, whole body
Full description
Migrated MorphoSource 1 Media File Title: STL, whole body Migrated MorphoSource 1 Media Group Title: CT scan of Cordylus angolensis
Creator
--
Date created
--
Date uploaded
August 12, 2016
Points
566,826
Polygons
1,193,219
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
76.599, 72.222, 15.441
Centroid coordinates
-23.121, 8.718, -5.670
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:herpetology:r-47333 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1400
Voltage
150
Power
0.018
Amperage
120
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000015862: Ct Scans Of Whole Body [CTImageSeries] [Etc] .

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000015862: Ct Scans Of Whole Body [CTImageSeries] [Etc] was processed to create derived Media 000015859: Whole Body Stl [Mesh] [Etc] (this media).

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000015859: Whole Body Stl [Mesh] [Etc] (this media)