Media 000017544: Cranium [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

Interactive/Embeddable Media Preview is currently unavailable. Please check back later.

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000017544
Media type
CTImageSeries
File format(s)
application/x-7z-compressed
File size
1,527,463,351 bytes
Object element or part
Cranium
Side
Midline
Orientation
--
Short description
Raw data - cranium of ROMV 1007 Ischyromys typus
Full description
Migrated MorphoSource 1 Media File Title: Raw data - cranium of ROMV 1007 Ischyromys typus Migrated MorphoSource 1 Media Group Title: Ischyromys typus ROMV 1007
Creator
--
Date created
--
Date uploaded
October 14, 2016
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
X pixel spacing
0.039463
Y pixel spacing
0.039463
Z pixel spacing
0.039463
Pixel spacing units
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
--
IP holder
Ornella Bertrand
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSERC Discovering grant to MTS and Pilot grant University of Toronto OB
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Ornella Bertrand provided access to these dataoriginally appearing in Bertrand and Silcox, in press , the collection of which was funded by NSERC Discovering grant to MTS and Pilot grant University of Toronto OB. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object rom:vertebrate palaeontology:1007 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
James Thostenson, Ornella Bertrand
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
--
Projections
2300
Voltage
155
Power
--
Amperage
186
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000017544: Cranium [CTImageSeries] [CT] (this media).

Processing Details

Creator
James Thostenson, Ornella Bertrand
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000017544: Cranium [CTImageSeries] [CT] (this media)