Media 000020804: Skull Scan
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000020804: Skull Scan
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
Media preview currently unavailable. Please check back later.
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000020804
Media type
Volumetric Image Series
Object element or part
Skull scan
Object represented
Object taxonomy
Geckolepis maculata
Object organization
Side
--
Orientation
--
Short description
DICOM stack
Full description
Migrated MorphoSource 1 Media File Title: DICOM stack Migrated MorphoSource 1 Media Group Title: micro-CT scan Migrated MorphoSource 1 Media File Description: Dimensions: 1233 x 865 x 1878\\r\\nResolution: 0.01288864 x 0.01288864 x 0.01288864 Migrated MorphoSource 1 Media Group Description: 1233 x 865 x 1878 voxels = 15.89 x 11.15 x 24.20 mm, 2002971510 voxels
Creator
--
Date created
--
Date uploaded
January 05, 2017
FILE OBJECT DETAILS Field Definitions
File name
Geckolepis-maculata_ZMB9655_skull_dicom.zip
File format(s)
ZIP archive, DICOM
File size
865 MB
Image width
1233
Image height
865
Color space
--
Color depth
8
Compression
--
X pixel spacing
0.012889
Y pixel spacing
0.012889
Z pixel spacing
0.012889
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,878
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix nanotom m, SNSB X-ray facility (Zoologische Staatssammlung München (Bavarian State Collection of Zoology))
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Mark D. Scherz provided access to these dataoriginally appearing in Scherz et al. 2017 PeerJ IN PRESS , the collection of which was funded by. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
zmb:9655
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix nanotom m
Device facility
SNSB X-ray facility (Zoologische Staatssammlung München (Bavarian State Collection of Zoology))
Creator
Mark D. Scherz
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.750
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
2440
Voltage
100
Power
--
Amperage
100
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000020804: Skull Scan [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Mark D. Scherz
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000020804: Skull Scan [CTImageSeries] [Etc] (this media)