Media 000028820: Element Unspecified [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
2 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000028820
Media type
CTImageSeries
Object element or part
--
Side
--
Orientation
--
Short description
Leporinus nigrotaeniatus - slice data isolated
Full description
Migrated MorphoSource 1 Media File Title: Leporinus nigrotaeniatus - slice data isolated Migrated MorphoSource 1 Media Group Title: Leporinus nigrotaeniatus
Creator
--
Date created
--
Date uploaded
July 16, 2017
FILE OBJECT DETAILS
File format(s)
image/jpeg
File size
16.3 MB
Image width
346
Image height
320
Color space
--
Color depth
8
Compression
--
X pixel spacing
0.049700
Y pixel spacing
0.049700
Z pixel spacing
0.049700
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,458
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
Oregon State University
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701665
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Oregon State University provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
os:fishes:18498
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Thaddeus Buser
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
60
Power
--
Amperage
133
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000027955: Element Unspecified [CTImageSeries] [Etc]
.
Processing Details
Creator
Thaddeus Buser
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000027955: Element Unspecified [CTImageSeries] [Etc]
was processed
to create
derived
Media 000028820: Element Unspecified [CTImageSeries] [Etc]
(this media).
Processing Details
Creator
Thaddeus Buser
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000028820: Element Unspecified [CTImageSeries] [Etc] (this media)