Media 000034195: Element Unspecified [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000034195
Media type
CTImageSeries
Object element or part
--
Side
--
Orientation
--
Short description
USNM 195830 whole body
Full description
Migrated MorphoSource 1 Media File Title: USNM 195830 whole body Migrated MorphoSource 1 Media Group Title: Whole specimen scan of Satan eurystomus USNM 195830
Creator
--
Date created
--
Date uploaded
October 16, 2017

FILE OBJECT DETAILS

File format(s)
image/jpeg
File size
77.1 MB
Image width
743
Image height
589
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
0.031600
Y pixel spacing
0.031600
Z pixel spacing
0.031600
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,301

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Dean A. Hendrickson provided access to these dataoriginally appearing in , the collection of which was funded by. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object usnm:fishes:195830 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
18010
Voltage
130
Power
--
Amperage
0.46
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000034195: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Matthew Colbert
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000034195: Element Unspecified [CTImageSeries] [Etc] (this media)