Media 000037556: Jaw
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000037556
Media type
Mesh
Object element or part
Jaw
Object represented
Object taxonomy
Atractaspis bibronii bibronii
Object organization
Side
--
Orientation
--
Short description
STL of Jaw
Full description
Migrated MorphoSource 1 Media File Title: STL of Jaw Migrated MorphoSource 1 Media Group Title: CT scan of CAS11670, Atractaspis bibronii bibronii Migrated MorphoSource 1 Media Group Description: Specimens moved during scan- some blurring artifacts
Creator
--
Date created
--
Date uploaded
November 20, 2017

FILE OBJECT DETAILS Field Definitions

File name
CAS111670-jaw.stl
File format(s)
STL
File size
3.76 MB
Points
39336
Polygons
78844
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
13.025, 5.950, 4.689
Centroid coordinates
-1.914, 3.093, -8.669
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, GE Sensing & Inspection Technologies / phoenix|x-ray (Baker Hughes)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
California Academy of Sciences
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object CAS:HERP:111670 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
GE Sensing & Inspection Technologies / phoenix|x-ray (Baker Hughes)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.333
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1000
Voltage
100
Power
0.016
Amperage
160
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000037556: Jaw [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000037556: Jaw [Mesh] [Etc] (this media)