Media 000042678: Dicom Stack
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000042678
Media type
Volumetric Image Series
Object element or part
DICOM stack
Object represented
Object taxonomy
Lepidochelys olivacea
Side
--
Orientation
--
Short description
microCT volume files
Full description
Migrated MorphoSource 1 Media File Title: microCT volume files Migrated MorphoSource 1 Media Group Title: microCT volume files and mesh files
Creator
--
Date created
--
Date uploaded
March 02, 2018

FILE OBJECT DETAILS Field Definitions

File name
Lepidochelys-olivacea-SMNS-11070-DICOM.zip
File format(s)
ZIP archive, DICOM
File size
2.39 GB
Image width
909
Image height
1132
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.100403
Y pixel spacing
0.100403
Z pixel spacing
0.100403
Pixel spacing units
Millimeters
Slice thickness
0.1004030
Number of images in set
1,541

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Cambridge Biotomography Centre (University of Cambridge)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
Staatliches Museum für Naturkunde Stuttgart (CT data); Serjoscha W. Evers (PLY files)
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NERC studentship to SWE on the DTP Environmental Research (NE/L0021612/1)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Serjoscha W. Evers provided access to these dataoriginally appearing in Evers & Benson (2018) , the collection of which was funded by a NERC studentship to SWE on the DTP Environmental Research (NE/L0021612/1). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object smns:11070 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Cambridge Biotomography Centre (University of Cambridge)
Creator
--
Event date
--
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
354 msec
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
170
Power
--
Amperage
396
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000042678: Dicom Stack [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000042678: Dicom Stack [CTImageSeries] [Etc] (this media)