Media 000043561: Element Unspecified [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

FILE OBJECT DETAILS

Media ID
000043561
Media type
CTImageSeries
File format(s)
image/tiff
File size
6,383,901,641 bytes
Object element or part
--
Side
--
Orientation
--
Short description
CMNH 24742 Viracarpon hexaspermum tiff stack
Full description
Migrated MorphoSource 1 Media File Title: CMNH 24742 Viracarpon hexaspermum tiff stack Migrated MorphoSource 1 Media Group Title: CMNH 24742 Viracarpon hexaspermum
Creator
--
Date created
--
Date uploaded
March 13, 2018
Image width
1759
Image height
1413
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.01612
Y pixel spacing
0.01612
Z pixel spacing
0.01612
Pixel spacing units
Mm
Number of images in set
1,739

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Nikon Metrology, Tring (Nikon Metrology, Tring)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF EAR 1338295 and 1338285
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object cmnh:pb:24742 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Nikon Metrology, Tring (Nikon Metrology, Tring)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
--
Projections
--
Voltage
100
Power
--
Amperage
145
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000043561: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000043561: Element Unspecified [CTImageSeries] [Etc] (this media)