Media 000048180: 16bit Tiffs
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000048180
Media type
Volumetric Image Series
Object element or part
16bit tiffs
Object represented
Object taxonomy
Ichthyophis laosensis
Object organization
Side
--
Orientation
--
Short description
Zstack
Full description
Migrated MorphoSource 1 Media File Title: Zstack Migrated MorphoSource 1 Media Group Title: CT scan of NCSM-herp-86611, Ichthyophis laosensis
Creator
--
Date created
--
Date uploaded
May 08, 2018

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
622 MB
Image width
1186
Image height
546
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.024667
Y pixel spacing
0.024667
Z pixel spacing
0.024667
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,020

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Florida Museum of Natural History
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object NCSM:Herp:86611 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
2200
Voltage
90
Power
0.0144
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000048180: 16bit Tiffs [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000048180: 16bit Tiffs [CTImageSeries] [Etc] (this media)