Media 000048271: Cranium
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000048271
Media type
Mesh
Object element or part
Cranium
Object represented
Object taxonomy
Hystrix cristata
Object organization
Side
--
Orientation
--
Short description
Surface reconstruction
Full description
Migrated MorphoSource 1 Media File Title: Surface reconstruction Migrated MorphoSource 1 Media Group Title: MicroCT volume
Creator
--
Date created
--
Date uploaded
May 10, 2018

FILE OBJECT DETAILS Field Definitions

File name
Hystrix-skull-surface.ply
File format(s)
PLY
File size
476 MB
Points
6112514
Polygons
12234232
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
146.095, 85.919, 73.506
Centroid coordinates
75.347, 50.709, 36.279
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX 160, Department of Engineering (Medical and Biomedical) (University of Hull)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object umzc:E.3406 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology HMX 160
Device facility
Department of Engineering (Medical and Biomedical) (University of Hull)
Creator
Sue Taft
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived private media that exists on MorphoSource but is inaccessible with current user permissions.

Processing Details Field Definitions

Creator
Sue Taft
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Private media inaccessible with current permissions

STEP 3: IMAGE PROCESSING

Derived private media was processed to create derived Media 000048271: Cranium [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Sue Taft
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000048271: Cranium [Mesh] [Etc] (this media)