Media 000050107: Dentary
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000050107
Media type
Mesh
Object element or part
dentary
Object represented
Object taxonomy
Mycterosaurus longiceps
Side
Right
Orientation
--
Short description
mesh file
Full description
Migrated MorphoSource 1 Media File Title: mesh file Migrated MorphoSource 1 Media Group Title: micro-CT volume files and mesh files
Creator
--
Date created
--
Date uploaded
June 14, 2018

FILE OBJECT DETAILS Field Definitions

File name
Mycterosaurus_right-dentary_001.ply
File format(s)
PLY
File size
1020 KB
Points
23684
Polygons
47336
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
3533.241, 10293.547, 6243.978
Centroid coordinates
6029.963, 59536.444, 11234.640
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
David P. Ford (.ply files); Sam Noble Oklahoma Museum of Natural History, University of Oklahoma (CT data)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NERC studentship to DPF on Oxford DTP Environmental Research NE/L0021612/1
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: David P. Ford provided access to these dataoriginally appearing in Ford and Benson 2018 , the collection of which was funded by a NERC studentship to DPF. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:UC:692 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
April Isch
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
3071
Voltage
135
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000056528: Posterior Mandible [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
April Isch
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000056528: Posterior Mandible [CTImageSeries] [CT] was processed to create derived Media 000050107: Dentary [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
April Isch
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000050107: Dentary [Mesh] [Etc] (this media)