Media 000064710: Articulated Hand
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000064710
Media type
Volumetric Image Series
Object element or part
Articulated Hand
Object represented
Object taxonomy
Cynocephalus sp.
Side
Right
Orientation
--
Short description
Zipped Tiff Stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped Tiff Stack Migrated MorphoSource 1 Media Group Title: microCT Volume File Migrated MorphoSource 1 Media File Description: Correct chirality Migrated MorphoSource 1 Media Group Description: Correct chirality
Creator
--
Date created
--
Date uploaded
November 27, 2018

FILE OBJECT DETAILS Field Definitions

File name
EA-Dermoptera-R-Hand.zip
File format(s)
ZIP archive, TIFF
File size
339 MB
Image width
619
Image height
814
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
0.053536
Y pixel spacing
0.053536
Z pixel spacing
0.053536
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,829

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Doug Boyer
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF BCS 1552848 (to DM Boyer)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these data , the collection of which was funded by NSF BCS 1552848 (to DM Boyer). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object du:ea:469 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Mackenzie Shepard
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
130
Power
0.01365
Amperage
105
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000064710: Articulated Hand [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Mackenzie Shepard
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000064710: Articulated Hand [CTImageSeries] [Etc] (this media)