Media 000067506: Braincase
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000067506
Media type
Mesh
Object element or part
Braincase
Object represented
Object taxonomy
Xenopus wittei
Object organization
Side
--
Orientation
--
Short description
Mesh file (stl)
Full description
Migrated MorphoSource 1 Media File Title: Mesh file (stl) Migrated MorphoSource 1 Media Group Title: MicroCT and derivatives of amnh:herpetology:a-101266, Xenopus wittei
Creator
--
Date created
--
Date uploaded
January 24, 2019

FILE OBJECT DETAILS Field Definitions

File name
Xenopus-wittei-AMNHA101266.stl
File format(s)
STL
File size
1.1 MB
Points
11456
Polygons
22994
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
8.218, 6.428, 8.689
Centroid coordinates
3.928, 0.767, 22.456
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
American Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Herpetology:A-101266 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.333137
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1000
Voltage
100
Power
0.02
Amperage
200
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000067421: Element Unspecified [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000067421: Element Unspecified [CTImageSeries] [Etc] was processed to create derived Media 000067506: Braincase [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000067506: Braincase [Mesh] [Etc] (this media)