Media 000068090: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000068090
Media type
Volumetric Image Series
Object element or part
Skull
Object represented
Object taxonomy
Galeopterus variegatus
Side
--
Orientation
--
Short description
Tiff Stack
Full description
Migrated MorphoSource 1 Media File Title: Tiff Stack Migrated MorphoSource 1 Media Group Title: CT scan tiff stack
Creator
--
Date created
--
Date uploaded
January 30, 2019

FILE OBJECT DETAILS Field Definitions

File name
Galeopterus_16bitTiff.zip
File format(s)
ZIP archive, TIFF
File size
2.29 GB
Image width
1098
Image height
710
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.040400
Y pixel spacing
0.040400
Z pixel spacing
0.040400
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,873

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Ingrid Lundeen provided access to these dataoriginally appearing in Lundeen and Kirk (2019) , the collection of which was funded by E. C. Kirk. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object l-eck:1 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
6 gain calibrations, 5 mm calibration phantom, data range [-1.0, 13.0] (grayscales adjusted from NSI defaults), beam-hardening correction = 0.15
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
1845
Voltage
150
Power
--
Amperage
0.12
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000068090: Skull [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000068090: Skull [CTImageSeries] [Etc] (this media)