Media 000074905: Cuboid
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000074905
Media type
Mesh
Object element or part
Cuboid
Object represented
Object taxonomy
Macaca sp.
Side
Right
Orientation
--
Short description
Raw surface file
Full description
Migrated MorphoSource 1 Media File Title: Raw surface file Migrated MorphoSource 1 Media Group Title: Zipped tiff stack Migrated MorphoSource 1 Media Group Description: Reverse chirality
Creator
--
Date created
--
Date uploaded
April 11, 2019

FILE OBJECT DETAILS Field Definitions

File name
DPC073_Macaca_R_cuboid_raw.ply
File format(s)
PLY
File size
90 MB
Points
1221958
Polygons
2444438
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
11.209, 13.611, 15.212
Centroid coordinates
18.639, 19.694, 42.582
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
Duke Lemur Center
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Gabriel Yapuncich provided access to these dataoriginally appearing in , the collection of which was funded by. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dpc:ost:73 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Emily Laub
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1600
Voltage
135
Power
--
Amperage
75
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000074900: Tarsals [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Emily Laub
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000074900: Tarsals [CTImageSeries] [Etc] was processed to create derived Media 000074905: Cuboid [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Emily Laub
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000074905: Cuboid [Mesh] [Etc] (this media)